Frequently Asked Questions about Gemini 1
Questions Click on questions to go to answer |
1. Warning about parking the mount and leaving power on. |
2. Why does the Gemini Stop and wait for startup instructions if the hand controller is not present? |
3. What is a ground loop and how can you test for one? |
4. How do you disable the Gemini modeling, to use T-Point or ACP |
5. Is it possible to use more than one USB-serial adapter at one time on a laptop? |
6. How do you install the ASCOM Driver in TheSKY6? |
7. How do you determine the COM Port of a connected USB to Serial Adapter and change it? |
8. What is the different between the old and new autoguider ports? |
9. How do you get Windows 2000, XP, Vista & Win7 to show all the COM ports that have been allocated? |
10. What are the changes between L4V1.02 and L4V1.04 EPROMS? |
11. How do you determine if the RS232 chip in the Gemini is bad? |
12. Can you run the Gemini without the motors connected safely? |
13. What will cause the Gemini to shut down the hand controller? |
14. What does the red dots on the hand controller mean during boot? |
15. How do you measure the CMOS RAM chip battery voltage and partial schematic? |
16. How should the guide cable from a ShoeStringAstronomy GPUSB be wired for the Gemini 2 or Gemini 1? |
17. How to test the Gemini-1 guider input circuit. |
18. What type of Battery does the Gemini 1 and Gemini-2 units use? |
19. Suggested replacement for the hand controller cable for Gemini-1. |
20. Extending the battery life of the 3V battery in an Gemini-1. This will also possibly help fix CMOS resets. This is a copy of message 3584 from the Gemini_Users Group. |
21. Some sources of the Gemini-1 Power plug. |
22. What does it take to add a second communication port to the Gemini Controller. |
Answers |
1. Warning about parking the mount and leaving power on? |
Answer: WARNING: The Gemini-1 has several Startup modes. If is your habit of leaving the Gemini-1 powered on and parked, when not in use, then you should always make sure that you use one of the two options below. This is because if you have a power failure, and then power is restored, and the mount is in Cold Start, Warm Start, or Warm Restart, then the RA motor will start running at the tracking rate set, and can possibility run your telescope into your roof, or a limit, without you knowing it until too late: 1. Set your startup mode to "ASK IF POSSIBLE." or 2. Put the telescope into terrestrial mode tracking after parking. Just remember to switch it back to Sidereal mode when starting up again. This is the safest option. |
2. Why does the Gemini Stop and wait for startup instructions if the hand controller is not present? |
Answer: The Gemini unit has to have either the hand controller or an external computer to tell it which mode to boot in. When the Gemini initializes, it looks to see if a hand controller is connected, or some other type of communications adapter is connected to the DB15 pin connector. If it detects a hand controller, then it will go ahead and send out the display commands to the hand controller. If a hand controller is not present, or a Second Serial Port adapter is present, then the Gemini will stop and wait for a signal into either the normal RS-232 port or the Second Serial Port, to tell it that a computer or PDA or some kind of controlling device is present. The controlling device has to be able to tell the Gemini what mode to start up in. |
3. What is a ground loop and how can you test for one? |
Answer: A ground loop is a difference of potential in voltage between connected devices. It is normal to have a small difference due to the resistance in cables and connectors. However it should not be more than 1 volt in practice. Here is a good article that explains ground loops:
Ground Loops Article
Answer for how do you test for one. Ground loops and power supplies are tricky thing. Take these steps to find out if you have a possible ground loop. 1. Turn off all power supplies. Leave the power supplies plugged into the house current. 2. Disconnect all power supplies from the Gemini and camera. Leave the one to the computer plugged in. 3. Measure with an ohm meter between the Gemini power pins of the VCD OUT GND pin (see page 131 of L4 manual) on the Gemini to the Ground pin of the Camera and then a ground spot on the Computer. Also measure between the camera and computer. A reading of NO ohms would be perfect. Any low reading could mean you might have a ground loop. This means that the power supply input is not isolated from the power supply output. 4. Next turn all power supplies on. Measure for voltage between the ground outputs to each other. A zero reading is good. anything above 1 volt is bad. Voltage between 0 and 1 volt can also be bad, but depends on how large you wires are. Remember that you are doing this with no/very little current flowing. 5. Reconnect the camera, Gemini and computer. do step 4 with them connected. and see what you have. They should not have changed much. Again voltage between the units is a bad thing. Computers can cause ground loops because they normally get connected to many other powered devices like monitors, networks and printers through wires. The best way to eliminate ground loops is to have all the neutral (ground) DC output of every device tied to a central point, through a heavy (12 Gauge) wire. The central point when using a Gemini would be the Gemini ground input pins. This is not easy to always do. The next best is opto or magnetic isolated inputs to the Guider and RS232 inputs. If you do do a central ground between your devices, consider putting in a ground rod at least 8 ft deep next to the central point into the ground. This can help prevent static damage. The best preventive is to use Isolated RS232 or USB adapters and Guiders into the Gemini. They can eliminate ground loops. I use one on all inputs to my Gemini. Of course I manufactured my own. One word on note: The Gemini's with the slide switch for power do not have the electronics grounded to the case. The Gemini's with the Toggle switch do have the electronics grounded to the case. |
4. How do you disable the Gemini modeling, to use T-Point or ACP |
Answer: If using the ASCOM driver for your mount? Go into the driver setup and click first on the "Modeling Parameters"
button. This should show all zeros. If it does not, click on "Clear Parameters"
and store the clear out in your Gemini. Now go back to the main setup window and
click on "Advanced Setup". In the top right of the window that opens you should
see a check box with "Sync Mode Affects Model (Additional Align)". Make sure this is UN-checked. Otherwise every time you do a sync you will be adding to a Gemini model which would adversely interact with the TPoint model. While you are in there, uncheck precession and refraction calculations, as TheSky does this itself. |
5. Is it possible to use more than one USB-serial adapter at one time on a laptop? |
Answer: Yes. You can use as many as you have USB ports. Please note that each
one will be assigned a Serial port number according to which one is plugged into which
port. Each USB to Serial Adapter has a unique serial number. So lets say that your
first RS-232 adapter has serial number 2001 and your second has serial number 4001.
Lets also say that you have 3 USB ports on your laptop called 1, 2 and 3.
Now lets say that you plug RS-232 #2001 adapter into USB port 1. The computer might
assign it Com port 3,
Now lets say that you unplug adapter #2001 and plug in adapter 4001 into USB port 1, The computer might assign it to Com 4. Now lets say that you plug adapter #2001 into USB port #2. The computer might assign it to Com 5. As you can see, XP uses the adapters serial number and which USB port to assign the serial ports. My recommendation is mark each adapter to which USB port you are plugging it into, and always use the same setup. That way you will continue to use the same predictable COM port setting. |
6. How do you install the ASCOM Driver in TheSKY6? |
Answer: If you downloaded the
TeleAPI package from the ASCOM web site, Downloads
section, Plugins, the zip file you have contains a ReadMe file that says:
This plugin allows Software Bisque's TheSky to communicate with ASCOM-compliant telescopes via TheSky's "TeleAPI" feature. Installation
|
7. How do you determine the Com Port of a connected USB to Serial Adapter and change it? |
Answer: These instructions work only for Windows XP.
|
8. What is the different between the old and new auto-guider ports? |
Answer: Directly from the manual:
4.2.1 The Autoguider Port. IMPORTANT: There are two different versions of the Gemini Autoguider port hardware. The versions can be distinguished by the type of connectors used for the motor cables. The older Gemini version uses RJ-45 modular connectors, and the newer version uses 6-pin DIN connectors. The primary difference between the versions is that the older Gemini Users Manual version 4.1 paragraph 4.2.1 says the guider port does not directly support autoguiders with TTL output, but the newer version does. Gemini contains a separate Autoguider port a 6-pin modular RJ-11 socket located below the 15-pin connector to the left. It contains a common pin, four directional pins and one pin that is controlled by the alarm signal that can be used for shutter control. The common pin of the RJ-11 modular connector is connected to +5V on the older version of Gemini, and GND on the newer version. The 4 directional inputs must be connected to the common pin to be active (they are active at High potentials on the older version of Gemini, and at Low potentials on the newer version). Simultaneously activating opposing directional signals (DEC+ and DEC- or RA+ and RA-) will be ignored and displayed as Autoguider Error. Note: The autoguider port is only active in the Photographic Mode and All- Speeds Mode of the Gemini system. Selecting the Visual Mode disables Guiding and therefore the Autoguider Port. More from the manual: 4.2.2 Manual Guiding Manual guiding is usually done using an eyepiece with an illuminated reticle attached to an off-axis guider or separate guidescope. You center a star (or the object being photographed) in the reticle and use the buttons on the Deluxe Hand Controller to apply guiding corrections to keep the star on the reticle throughout the duration of the exposure. Rather than using the Deluxe Hand Controller, you can instead guide with a Losmandy Standard Hand Controller plugged into the autoguider port. The LED of the Standard Hand Controller will not normally be lit, but will light up anytime the alarm sounds. Using a Standard Hand Controller in the autoguider port has a big advantage for manual guiding, in that accidentally pressing opposite directional buttons simultaneously will not result in movement at centering speed, as happens with the Hand Controller in its normal socket, or when using the Deluxe Hand Controller. This reduces the risk of spoiling a long exposure photograph due to an accidental key press. In either case, you will need to make sure that the Hand Controller is set to either the Photographic or All-Speeds Mode. 4.2.3 Connecting an Autoguider to an Older Gemini: 4.2.3.1 Connecting an Autoguider with Relay Output Autoguiders with relay outputs (such as the SBIG ST-4) can be connected to the Gemini system directly. Simply connect one side of each of the four relay contacts to the Autoguider input common pin, and connect the other side of each relay to the appropriate direction input pins of the autoguider port. Cables are available for most compatible autoguiders to plug directly between the autoguider and Gemini. Gemini Users Manual 42 4.2.3.2 Connecting an Autoguider with TTL Output: The typical "open collector" output stage (e.g. the ST-7/8/9/10, user-modified ST-4) has high impedance while inactive and pulls down the direction signals to a common ground when active. This is exactly the opposite of the way the Hand Controller and autoguider ports of the older version Gemini system work. A relay (or optocoupler) decouples the switching device (the Autoguider) from the controlled device (the Gemini), thereby avoiding a direct connection between the two systems and protecting both systems against high currents that could cause damage. IMPORTANT NOTICE: (1) Never connect TTL output stages directly to the Hand Controller or autoguider ports of an older version Gemini! Severe damage may occur to the connected devices. Use a Relay Box (as provided by SBIG) or the optional Losmandy Optocoupler unit instead. By so doing, you get the additional advantage of providing electrical protection to these sensitive units. (2) The use of two separate power supplies without a coupler unit is strongly discouraged. To do so would connect the ground of one system to the supply voltage of the other system, causing the two grounds to be at different potentials. If the grounds of the two systems are then connected, severe damage is likely to occur. Detailed instructions for connecting an SBIG camera with TTL outputs to the older version of Gemini can be found in Appendix 8.6 (Autoguider Port). 4.2.4 Connecting an Autoguider to a Newer Gemini The Autoguider port on the newer versions of Gemini is plug compatible with a large variety of autoguiders. You can use an autoguider with relay outputs such as the SBIG ST-4 and STV or an autoguider with TTL outputs such as the SBIG ST-7/8/9/10 directly using the appropriate cable. Use SBIGs TIC cable for the ST-4 and STV, and SBIGs TIC-78 cable for cameras with TTL output. The SBIG relay box can be used, but is not necessary. The Losmandy Optocoupler is not compatible with the newer Gemini. Also Note that the Common pin is not ground on the Newer style Gemini's. It is pulled to ground through a 100 ohm resistor. All the guider inputs are pulled to +5V through 3.3K ohm pullups. I highly recommend the USB Guide Port interface for OLD Gemini called GPUSB-AH from http://www.store.shoestringastronomy.com/products_gp.htm if you have the older version of the Gemini-1 boards, which have RJ-12 jacks for motor connectors. You will also need the correct guide cable to go with it. The one supplied by S-Big if you have a SBig camera will not work. |
9. How do you get Windows 2000, XP, Vista & Win7 to show all the COM ports that have been allocated? |
Answer: Windows does not normally show non-connected devices in device manager. This is even true if you turn on show hidden devices under the view tab. Before you do this change, be for warned - that this will let you modify/delete devices that you might not want changed or deleted. You do this at your own risk!. With that said here is a step by step process. You can also see how to do this on the Microsoft's web site at:
http://support.microsoft.com/kb/241257
For 2000 and XP:
The trick was to open the Command Prompt as administrator and start the Device Manager from the same command prompt.
Now if you expand the section on COM ports, all the COM ports that have ever been created will be displayed, the non present ones being in grey. You can uninstall away anything that you don’t want (right click, select uninstall). "http:/www.fettesps.com/how-to-remove-com-ports-which-are-in-use/ |
10. What are the changes between L4V1.02 and L4V1.04 EPROMS? |
Answer: This version has the following updates over L4V1.02:
|
11. How do you determine if the RS232 chip in the Gemini is bad? |
Answer: Please read all this paragraph before attempting to test. The problem is normally with the negative voltage pump in the IC. This normally only takes out the transmit side of the chip (sending signals to the PC) and leave the receive side good. So if you cannot connect to a PC, but can connect a GPS, and receive GPS updates, this is a good indication also the negative voltage pump is bad. The sure fire test requires voltage testing. You can check this out if you have a good Voltmeter. Please do this only if you feel comfortable doing this as you do it at your OWN RISK. The cap number is C21 in the newer boards with the round motor cables. Measure across this cap with you voltmeter with the Gemini powered up. It is best if you have a friend do the meter reading while you hold the leads. Micro-leads is highly recommended for this. The lead closest to the IC is the negative lead. The side closest to the RJ22 connectors is the ground side. This cap comes off of Pin 7 of the IC, which should be marked with 3221 if I remember correctly. If you do not get a 5 Volt reading or close to that then the IC has gone bad (or been put to sleep, see note below) and needs to be replaced. The Gemini is sensitive to ground loops, and they can take this IC out. This has been the problem in all the cases I have found except one. That had a bad cap and broken trace. Please NOTE that this chip has an auto sleep mode that can also shut down the transmit part of the IC. If the IC has shut down the transmit part of the IC to save power, this voltage will also measure zero. To wake up the IC, ask the Gemini to get GPS data, or send it a command such as trying to connect using GCC. Any command that requires the Gemini to send a reply should wake the IC up. Also note: |
12. Can you run the Gemini without the motors connected safely? |
Answer: Yes you can power up the Gemini without the motors connected. You will get motor stall/stopped errors. You can stop these errors by putting the Gemini in the terrestrial mode. Setup->>Mount Parameters->>Tracking Speed->>None/Terrestrial. |
13. What will cause the Gemini to shut down the hand controller? |
Answer: Micro Resettable Fuse F2 for Gemini. This fuse is a resettable fuse that protects the +5V circuit. If it drops to much voltage, the processor will shut down the +5V power supply in the controller. A symptom of this is the Gemini turning off the hand controller when plugging in a RS232 device into the RS232 Jack, or a Guider into the Guider Jack, or a GPS into the Feature Port. Basically anything that causes more +5V current drain can cause this symptom with a bad fuse. In the older Gemini's it was Green and marked X14. If your fuse is marked X14 and normally green in color, then you have the older fuse. The fuse shown in the picture is the newer higher rated fuse, but still green in color. It can be black in color and be the correct higher rated fuse. This was a known problem (according to René Görlich's) and later units was shipped with the higher rated fuse to prevent this from happening. All units shipped with the rocker switch should have the newer fuse. |
14. What does the red dots on the hand controller mean during boot? |
Answer: The characters at boot time indicate the boot
progress and conditions detected. 1st dot: internal resources and display initialized 2nd dot: power good, voltage stabilized 3rd dot: SRAM accessible (otherwise "SRAM failure !" will be displayed) X: the content of the SRAM was reset to default values. R: RTC was reset ("RTC malfunction" displayed if RTC is not working) 4th dot: RTC initialized 5th dot: SRAM values loaded. "AG port defect ? " will be displayed if one or more AG signals are active. The X is to be expected after a version change, battery change, at low battery voltage and so on. Once it appears, a "CMOS reset" string is appended to the startup message, too. Since the initializing is done by the same subroutine as used by the Setup...Reset Defaults menu point, there is no need to take the battery out to renew the SRAM content. A side effect of pulling the battery out is that the RTC chip will stop working after a while and may then be initialized at the next startup. In case of problems you may first check and maybe set the UTC date and time and the ALARM time, too. |
If the second dot is not displayed and the boot process stops, the board
voltage does not stabilize at the nominal 5V voltage either F2 may have to
be replaced, or U3 has gone bad. Try to remove peripherals in this case (AG, serial
connection, feature port peripherals, axes encoders may draw too much
current) and boot again, to test and see if F2 is acting up.
U3, (image to the right) a MCP809-450 Voltage monitor can also keep the Gemini-1 from booting past the first dot on the Deluxe Hand controller. This IC is used to shut down the system (a brown-out detector) and let values be stored so that Warm Restart works properly. About the only way to test for U3 being bad is to remove it. |
There is a unused connection from the battery to an analogue input pin of the CPU to check the voltage - R32 was removed since the CPU chip drew some current from the battery while being powered off, shortening battery life. The above answers are a direct quote from René Also there is another known problem, which is C3 a 4.7uf 10Volt cap directly above the processor. This cap is what resets the Gemini processor at power up. It is suppose to hold the Processor in reset while the power stabilizes. If it is not holding the processor in reset long enough, then the processor might not be starting up correctly. A quick test of this is to take a pair of fine needle nose-pliers/tweezers and short across this cap for about 1/2 sec. Then remove the pliers/tweezers. If the Gemini then boots ok, it could be an indication that this cap is loosing it value, or it's pull-up resistor R45 (a 10K) value has also changed. This cap has also been known to break loose from the circuit board. |
15. How do you measure the CMOS RAM chip battery voltage and partial schematic? |
Answer: You would need a voltmeter to measure across pins 16 and 32 of the Static Ram chip. This is done with power off, and power disconnected from the Gemini. It would be safer to disconnect everything from the Gemini. Again, you do this at your own risk. You should measure a voltage above +2.8 VDC If you measure less than that you probably have a bad battery, or one of the steering diodes has gone out. If you power on the Gemini this voltage should jump up to +5VDC. If either of the voltage measurements are not correct, it is probably the steering diode D1 (BAT54C Schottky diode). If both is bad then it has to be the Steering diode D1 or C8 a 0.1uF cap has shorted. Of course the Ram chip could also be bad, and pulling the voltage down. |
Note
that R32 and U21 are not on the PCB. The bottom part of the
schematic to the left is the Static Ram Chip U9 which is also
pictured extreme left on the PCB. All of the +VB connect together. VCC is +5V. Also note that the battery type in the schematic is shown as CR2354 but the schematic is the same for units with battery type CR2032. |
16. How should the guide cable from a ShoeAstronomy GPUSB be wired for the Gemini 2 or Gemini 1? |
Answer: Here is a link to a wiring diagram provided with the permission if ShoeStringAstronomy that tells how to make the cable that goes from the GPUSB or GPUSB-AH into the Gemini-2 or Gemini-1. Note that only the GPUSB is compatible with the Gemini-2, or the Gemini-1 with round motor cables. Here is the link to the guide_port_cables.pdf. |
17. How to test the Gemini-1 guider input circuit. |
Answer: Here is a schematic of the Gemini-1 input guider circuit. Note
this is for the Gemini-1 with round motor connectors.
It can be tested with a voltmeter. You can click on the image to get
a larger one. The input jack is on the right. There are
4 pull-up, one on each input lead that pulls the inputs up to about
+5 Volts. These inputs are feed to a hex inverter IC.
(74HC04) (In the Gemini-1 units with the RJ style motor connectors,
this IC is missing, and the leads go directly into the
microprocessor. Also the resistors are to ground instead of
+5Volts) Now if you make a test cable where you can short each input going into the Guider Jack, one at a time, to Guider Pin 2, and put a voltmeter on the output side of the Hex inverter, you can test each input to see if it is working. Lets say we short pins 2 and 3 together on the input. This would put a low signal level on pin one of the IC U23. When this happens the pin 2 of this IC should change from a low (around 0 volts) to something between 4 and 5 volts. If you do this to all the input pins one at a time, and all the output are good, then the guider circuit is ok. If none of the outputs change, then either the IC U23 or R42 is open. You can test to see if R42 is open by using an ohmmeter (with power off on the Gemini-1) and see if it measures 100 ohms. If it does, then more than likely U23 has gone bad. Note: U23 is not an easy IC to replace. It is a surface mount IC. The best way is to cut off the leads one at a time, then remove the body, and then un-solder each lead. Do not use too much heat, as you can lift the runs and also damage the runs that run under the IC. It is best to let a professional do this. Hope this helps eliminate your problems. |
18. What type of Battery does the Gemini 1 and Gemini-2 units use? |
Answer: The Gemini-1 has used 2 different types of batteries. In any of the units that have a slide switch for power, the
Battery is a CR-2032. It the newer Gemini-1 units that use a
toggle switch for power, the battery is a CR-2354. The battery in the Gemini-2 is a CR-2354. This battery powers the Real Time Clock and SRAM. After replacing this battery, you need to power up the Gemini-2 and then set the time. When setting the time, remember to do the store setting, or it will not be saved. This is because the processor will drain the battery if this is not done. It is a known flaw that is documented in the data sheet for the processor that is being used in the Gemini-2 units. |
19. A suggested hand controller cable replacement for the Gemini-1. |
Answer: A suggested replacement is available from http://cablewholesale.com with part number 10D2-01210 |
20. Extending the battery life of the 3V battery in an Gemini-1. This will also possibly help fix CMOS resets. This is a copy of message 3584 from the Gemini_Users Group. |
Answer:
I (René) can offer a solution now. Gemini's SRAM is not only used to store user catalogues and the observation logs, but also an amount of parameters and matrices used for the modeling algorithm. So it has a size of 128 KByte and is accessed (also for writing) very often, far exceeding size and reprogramming life time of an EEPROM. Normally, the Li CR2032 battery should last at least one year and should keep the SRAM content safe and the RTC running. If CMOS Resets occur after some minutes even with a fresh battery or battery lifetime is significantly shorter than one year, I recommend the following patch for the electronically inclined: 1) Buy a small 39k resistor (with wires, not SMD) 2) Solder it between pin 2 (the second from above at the left side) and pin 9 (the down most at the left side) of the EPSON real time clock chip labeled U2. The left side of the RTC is next to the SRAM chip U9. You can do this on the component side or the soldering side of the board. Power Gemini on/off. Wait. The CMOS resets should be gone. 3) Remove R38 to save Li battery power. Check again. This was tested with three different boards, one of them had CMOS Resets. All work fine. Scott has put out a movie on changing the battery. |
21. Some sources of the Gemini-1 power plug. |
Answer: These links was provided by Brendon on the Losmandy
Users Group
|
22. What does it take to add a second communication port to the Gemini Controller? |
Answer: This can now be done using the ASCOM Gemini.net driver. This driver has the capability of supporting a virtual serial port driver (called a Pass-Through port) such as VSPE. With this driver, you can add any non-ASCOM program and have it talk to the Gemini in parallel with the ASCOM programs. This question used to be about the USB/RS232 Isolated to Gemini-1 HandController adapter. These units are no longer being manufactured. Here are some suggestions for Isolated adapters.
|